COMPRESSOR UNIT AIR FILTER HAS SHORT LIFESPAN - PORTABLE AIR COMPRESSOR (PAC) -
Continued
CORRECTIVE ACTION - Continued
MALFUNCTION
Improperly cleaned primary air filter.
CORRECTIVE ACTION
Properly clean primary air filters (Figure 1) and verify primary air filter lifespan returns to normal
AIR
FILTERS
WWDS00270
Figure 1.
Air Filters.
a.
If primary air filter lifespan returns to normal, problem solved.
b.
If primary air filter lifespan does not return to normal, proceed to next Malfunction -
Incorrect shutdown procedure.
MALFUNCTION
Incorrect shutdown procedure.
CORRECTIVE ACTION
Verify proper shutdown procedure is used when turning off compressor unit (Volume 1,
WP 0059).
a.
If compressor unit air filter lifespan returns to normal, problem solved.
b.
If compressor unit air filter lifespan continues to be deteriorated, notify maintenance.