Figure 9. Battery Disconnect Switch
COMPRESSOR FAILS TO LOAD WHEN SERVICE AIR SWITCH IS PRESSED - PORTABLE AIR COMPRESSOR (PAC)

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  306    307    308    309    310  311  312    313    314    315    316  
img
. . .
TM 5-3820-276-10-2
0183
COMPRESSOR UNIT SHUTS DOWN UNEXPECTEDLY - PAC - Continued
CORRECTIVE ACTION - Continued
FUSE
FUSE
FUSE
F3
F2
F1
WWDS00215
Figure 10. Fuses F1, F2, and F3.
a.
If fuse F1, F2, or F3 is unserviceable (blown), replace with serviceable fuse of identical
amperage if readily available. Start engine and verify if PAC continues to run (Volume 1,
WP 0059). If the correct fuse is not readily available, notify maintenance.
b.
If fuse F1, F2, and F3 are serviceable (not blown), proceed to next Malfunction -
Compressor fault code present.
MALFUNCTION
Compressor fault code present.
CORRECTIVE ACTION
Check for compressor fault code(s) (WP 0178).
a.
If compressor fault code(s) are present, follow instructions given in compressor fault code
table (WP 0178).
b.
If compressor fault code(s) are not present, notify maintenance.
END OF WORK PACKAGE