Figure 2. Master Power Control Switch
Figure 6. Compressor Oil Level Sight Glass

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  302    303    304    305    306  307  308    309    310    311    312  
img
.
TM 5-3820-276-10-2
0183
COMPRESSOR UNIT SHUTS DOWN UNEXPECTEDLY - PAC - Continued
CORRECTIVE ACTION - Continued
LOW FUEL
LEVEL FAULT
INDICATOR
WWDS00274
Figure 4.
LOW FUEL LEVEL Fault Indicator.
a.
If fuel level is low, fill to appropriate level with fuel (Volume 1, WP 0056). Start engine and
verify if PAC continues to run (Volume 1, WP 0059).
b.
If fuel level is adequate for operation, proceed to next MALFUNCTION - High compressor
temperature fault indicator illuminated.
MALFUNCTION
High compressor temperature fault indicator illuminated.
CORRECTIVE ACTION
1.
Start and run compressor (Volume 1, WP 0059).
2.
Monitor HIGH COMPRESSOR TEMPERATURE fault indicator while waiting for failure to occur
(Figure 5).
HIGH COMPRESSOR
TEMPERATURE
FAULT INDICATOR
WWDS00242
Figure 5.
High Compressor Temperature Fault Indicator.
0183-3
02/13/2013root(tswp)wpno(T30008)