TM 5-3820-276-10-1
0054
AUXILIARY POWER UNIT (AC GENERATOR) SHUTDOWN - Continued
6.
Push engine speed switch (Figure 7, Item 2) to DOWN position and set engine speed to 850 rpm on RPM
gauge (Figure 7, Item 1).
1
2
WWDS00375
Figure 7.
MCS Engine Speed Switch Decrease.
7.
8.
Remove grounding clamp (Figure 8, Item 3) from grounding rod (Figure 8, Item 2).