Figure 3. MCS Engine Speed Switch Increase
Figure 5. AC Generator Control Panel (Power Off).

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  573    574    575    576    577  578  579    580    581    582    583  
img
.
TM 5-3820-276-10-1
0054
AUXILIARY POWER UNIT (AC GENERATOR) OPERATION - Continued
1
2
3
6
5
4
WWDS00067
Figure 4.
AC Generator Control Panel (Power On).
2.
Rotate two enclosure knobs (Figure 4, Item 2) and open control panel door (Figure 4, Item 6).
3.
Rotate GENERATOR switch (Figure 4, Item 3) to ON position.
WARNING
Do not attempt to perform any maintenance tasks on the generator during operation.
Serious electrical shock or death by electrocution may result. Failure to comply may result
in injury or death to personnel. Seek medical attention in the event of an injury.
4.
Rotate main power disconnect switch (Figure 4, Item 5) to ON position.
NOTE
Power is now available for use at electrical outlets on control panel.
5.
Make sure SYSTEM POWERED light (Figure 4, Item 4) is on.
END OF TASK
0054-5
02/13/2013root(opusualwp)wpno(O40008)