POST OPERATION PROCEDURES - MUD CLEANING SYSTEM (MCS)
Figure 3. Mud Pump Hose Disconnect (View 2)

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  579    580    581    582    583  584  585    586    587    588    589  
img
.
TM 5-3820-276-10-1
0055
MUD PUMP HOSE DISCONNECTION
NOTE
Mud pump outlet hose may not unscrew unless mud stand pipe switch on driller console
has been opened to relieve pressure.
1.
Disconnect 2-1/2-in. (63.5 mm) hose (Figure 2, Item 4) from mud pump outlet (Figure 2, Item 3).
1
3
4
2
5
WWDS00051
Figure 2.
Mud Pump Hose Disconnect (View 1).
2.
Pull safety cable wedge (Figure 2, Item 5) down to open loop in safety cable (Figure 2, Item 2).
3.
Remove safety cable (Figure 2, Item 2) from 3-in. (76 mm) outlet (Figure 2, Item 1).
4.
Disconnect 3-in. (76 mm) hose (Figure 3, Item 4) from drilling rig inlet (Figure 3, Item 3).
0055-2
02/13/2013root(opusualwp)wpno(O40009)