Figure 3. Mud Pump Hose Disconnect (View 2)
Figure 5. Sand Guzzler Hose Disconnect

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  581    582    583    584    585  586  587    588    589    590    591  
img
.
TM 5-3820-276-10-1
0055
SAND GUZZLER DISCONNECTION
1.
Disconnect 4-in. (102 mm) mud hose (Figure 4, Item 2) from mud pan (Figure 4, Item 3).
1
2
4
3
WWDS00080
Figure 4.
Hose Disconnect.
2.
Disconnect 4-in. (102 mm) mud hose (Figure 4, Item 2) from connector (Figure 4, Item 1) on side of MCS.
3.
Disconnect MCS case drain hose (Figure 4, Item 4) from sand guzzler case drain hose (Figure 5, Item 3).
WARNING
Do not open or disconnect hydraulic hoses or fittings while the hydraulic oil is hot or under
pressure. Hydraulic oil is flammable and harmful to the skin and eyes. The hydraulic tanks
and metal parts can be hot. Wear work gloves and eye protection when handling hydraulic
hoses, motors, and hydraulic parts. If hydraulic oil contacts skin, wash the affected area
immediately. In case of eye contact, flush with water for 15 minutes. Dispose of hydraulic
oil in accordance with standard operating procedures. Failure to comply may result in injury
or death to personnel. Seek medical attention in the event of an injury.
4.
Disconnect hydraulic hose (Figure 5, Item 4) from sand guzzler (Figure 5, Item 2).
0055-4
02/13/2013root(opusualwp)wpno(O40009)