• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 7. Manual Pump Operation.
Figure 9. Cleaning Valves Closed

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  485    486    487    488    489  490  491    492    493    494    495  
img
.
TM 5-3820-276-10-1
0041
MANUAL GROUT PUMP CLEANING OPERATION - Continued
8.
Using cleanup hose (Figure 8, Item 2), spray water to clean inside of grout mixing tank (Figure 8, Item 1).
1
2
WWDS00690
Figure 8.
Grout Mixing Tank Cleaning.
CAUTION
Do not run grout pump dry more than 10 seconds. Over heating of piston rubbers can
occur and cause damage to piston. Failure to comply may result in damage to equipment.
9.
Push GROUT PUMP flow divider lever (Figure 9, Item 2) to UP MAX. position to drain water from grout
mixing tank.
0041-8
02/13/2013root(opusualwp)wpno(O20018)