Figure 6. Cleaning Valves Closed
Figure 8. Grout Mixing Tank Cleaning

Technical Manual For Water Well Drilling System (Wwds) - 1 Page Navigation
  484    485    486    487    488  489  490    491    492    493    494  
img
.
TM 5-3820-276-10-1
0041
MANUAL GROUT PUMP CLEANING OPERATION - Continued
1
2
3
WWDS00768
Figure 7.
Manual Pump Operation.
4.
Set GROUT PUMP MANUAL switch (Figure 7, Item 3), as required, to manually move pump pistons.
5.
Set GROUT PUMP AUTO switch (Figure 7, Item 2) up to ON position.
6.
Push GROUT PUMP flow divider lever (Figure 7, Item 2) to UP MAX. position to drain water from tank.
7.
Push WATER PUMP flow divider lever (Figure 7, Item 1) up to ON position to turn water on.
0041-7