TM 10-4930-236-13&P4-17. VALVE OPERATING LEVER ASSEMBLYThis task consists of:a.Removalb.Disassemblyc.Repaird.Assemblye.InstallationINITIAL SETUPToolsRequiredGeneral Mechanic Tool Kit (Appendix B, Section III, Item 3)Materials/PartsRequiredGrease "Appendix E, Section II, Item 8)Dry Cleaning Solvent (Appendix E, Section II, Item 1)Rags, Wiping (Appendix E, Section II, Item 13)Lockwashers (4) (Appendix F)Spring Pin (1) (Appendix F)EquipmentConditionPumping Unit ShutdownGeneralSafetyInstructionsWARNINGDo not smoke within 50 feet (15.34 meters) of the Tank and Pump Unit.Dry cleaning solvent is potentially dangerous to personnel and property.NOTEDiscard all mandatory replacement parts.REMOVALa.Loosen nuts (1) to disconnect cables (2) from the adjusting bolts (3).b.Remove the nuts (1) and withdraw cables (2) through bushings (4).c.Remove screws (5) and lockwashers (6) to remove lever assembly (7) from pumping unit.4-38