TM 10-4930-236-13&PWARNINGAvoid breathing fumes generated by soldering. Eye protectionis required. Good general ventilation is normally adequate.b.Solder pins (10) to leads (9).c.Push pins (10) completely through rubber isolator (8).d.Install plastic collar (6) over rubber isolator (8).e.Push pins (10) into alinement barrel (7) as far as possible by hand, then pull pins through with needlenose pliers until pins seat within barrel.f.Slide plastic collar (6) fully into alinement barrel (7).g.Position metal collar (5) onto alinement barrel (7) and screw body (4) on alinement barrel.h.Tighten screws (3).4-37