TM 10-4930-236-13&P
INSTALLATION
a.
Install using new parts as required.
b.
Install leads (21, 22), washers (24) and screws (23) on receptacle (20).
c.
Insert leads (21, 22) through mounting hole and install receptacle (20), dust cap (19), flat washers
(18), lockwashers (17) and screws (16). Attach dust cap using screw (16) at lower right of receptacle.
WARNING
Avoiding breathing fumes generated by soldering. Eye
protection is required. Good general ventilation is normally
adequate. Ensure good ventilation.
d.
Install heat shrink insulation on wire, then solder leads (14 and 15) to terminals of receptacle (13).
Move heat shrink into position and apply heat. Install receptacle (13), dust cap (12), flat washers (11),
lockwashers (10) and screws (9). Use screw (9) at lower right of receptacle to attach dust cap (12).
e.
Install vent plugs (25) and coupling (2). Place the junction box (8) on the bracket and insert the motor
leads through the coupling (2). Screw the coupling nut (1) onto coupling (2).
f.
Install screws (7), flat washers (6), lockwashers (5) and nuts (4).
g.
Refer to procedures above and install the K1 relay and RF1 filter.
h.
Connect power cable and ON-OFF cable to junction box receptacles.
4-31