TM 10-4930-236-13&PCAUTIONDo not over-tighten nuts. Equipment damage can result fromover tightening.(9)Connect leads (3-7) and install lockwashers (9) and nuts (8).WARNINGSilicone compound, MIL-S-8660, is toxic to skin, eyes andrespiratory tract. Skin and eye protection required. Goodgeneral ventilation is normally adequate.(10)Apply silicone compound to O-ring packing (2) and install on cover (1). Install cover (1) andconnect power cable at receptacle J2.b.RemovalofRF1Filter.(1)Remove K1 relay (paragraph a. above).(2)Tag and disconnect the three leads (1) by removing nuts (2) and star washers (3).(3)Remove two screws (4), lockwashers (5) and flat washers (6).4-28