TM 10-4930-236-13&P
CAUTION
Do not over-tighten nuts. Equipment damage can result from
over tightening.
(9)
Connect leads (3-7) and install lockwashers (9) and nuts (8).
WARNING
Silicone compound, MIL-S-8660, is toxic to skin, eyes and
respiratory tract. Skin and eye protection required. Good
general ventilation is normally adequate.
(10)
Apply silicone compound to O-ring packing (2) and install on cover (1). Install cover (1) and
connect power cable at receptacle J2.
b.
Removal of RF1 Filter.
(1)
Remove K1 relay (paragraph a. above).
(2)
Tag and disconnect the three leads (1) by removing nuts (2) and star washers (3).
(3)
Remove two screws (4), lockwashers (5) and flat washers (6).
4-28