TM 10-4930-236-13&PNOTEFailure of motor thermostatic switch can prevent relay operation.(4)The “X” circuit of the relay is grounded through the thermostatic switch in the motor. To checkcontinuity, put probe on "X2” terminal of relay, and the other probe on negative (-) of the J2 connector.CAUTIONThe following tests require the power cable be connected as innormal pumping procedure. Exercise care in use of multimetertest probes.(5)Connect power cable to J2 and to vehicle NATO slave connector.(6)Hold negative (-) probe of multimeter on inner threaded portion of junction box for ground.(7)Touching positive (+) probe of multimeter to “A1” terminal of relay should give 24 + 2 voltreading.(8)All other terminals should have zero readings.(9)Place ON-OFF switch in ON position.(10)Ground negative (-) probe of multimeter as above.(11)Touching positive (+) probe of multimeter to "X1" terminal of relay should give 24 + 2 voltreading.(12)Touching positive (+) probe of multimeter to "A1" terminal of relay should give 24 + 2 voltreading.(13)Touching positive (+) probe of multimeter to “A2” terminal should give 24 + 2 volt reading.(14)Switch ON-OFF switch to the OFF position.4-26
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business