TM 10-4320-307-243-5 ENGINEENCLOSUREREPAIR .This task covers: Cleaning/lnspection/RepairINITIAL SETUPToolsManual ReferencesTool kit, general mechanic's (Item 1, Appendix B)TM 9-237GrinderEquipmentMaterials/PartsConditionDry cleaning solvent (Item 30, Appendix C)ReferenceCondition DescriptionPaint (Item 23, Appendix C)ParagraphEngine enclosure removedEmery cloth (Item 2, Appendix C)2-23Wire brushGeneral Safety InstructionsRespiratory protectionWell ventilated area required for cleaning, welding,and painting procedures.Personnel RequiredTwoCLEANING/INSPECTION/REPAIR:Dry cleaning solvent is potentially dangerous. Avoid repeated and prolonged breathing ofvapors and skin contact with the liquid. Do not use near open flame, arcing equipment, orother ignition source. Always wear eye protection and protective clothing.Death or serious injury could occur if compressed air is directed against the skin. Do notuse compressed air for cleaning or drying unless the pressure is/has been reduced to 30psi (2.11 kgcm2) or less. When working with compressed air always use chip guards, eyeprotection, and other personal protective equipment.3-7