TM 10-4320-307-24
3-7
FLEXIBLE COUPLING INSPECT/ALIGN/REPAIR/REPLACE .
This task covers:
a. Removal
b. Cleaning/lnspection/Repair
c. Installation
d. Alignment
INITIAL SETUP
Test Equipment
Manual References
Inside micrometer (Item 3, Appendix B)
TM 10-4320-307-10
Magnetic base dial/indicator set (Item 5,
General Safety Instructions
Appendix B)
Well ventilated area
Tools
Tool kit, general mechanic's (Item 1, Appendix B)
Torque wrench (Item 2, Appendix B)
Rubber hammer
REMOVAL:
1. Remove four bolts and washers (1) securing
protective cover (2) to engine enclosure and
remove cover.
2. Remove bolts (3) from standard hub (4) and hub
(5).
CAUTION
Do not pry apart hub grooves as this
may damage the machined surfaces.
3. Remove flexible coupling (6) with rubber
hammer.
3-11