LOW TANK LEVEL SWITCH REPLACEMENT
Figure 4. Low Tank Level Switch Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  1023    1024    1025    1026    1027  1028  1029    1030    1031    1032    1033  
img
.
TM 5-3825-270-23&P
0189
REMOVAL - Continued
7
8
9, 10, 11
12
Figure 2. Low Tank Level Switch Removal.
END OF TASK
INSTALLATION
NOTE
Install connectors as noted prior to removal.
Install low tank level switch as noted prior to removal.
1.
Install low tank level switch (Figure 3, Item 8) on bracket (Figure 3, Item 12) with retaining brackets (Figure 3,
Item 7), screws (Figure 3, Item 9), lockwashers (Figure 3, Item 10), and nuts (Figure 3, Item 11).
7
8
9, 10, 11
12
Figure 3. Low Tank Level Switch Installation.
2.
Install switch harness (Figure 4, Item 6) on two studs (Figure 4, Item 3) with retaining clips (Figure 4, Item 5)
and locknuts (Figure 4, Item 4).