Figure 4. High Tank Level Switch Installation.
Figure 2. Dial and Mounting Plate Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  1020    1021    1022    1023    1024  1025  1026    1027    1028    1029    1030  
img
. . . . . . .
TM 5-3825-270-23&P
0188
FIELD MAINTENANCE
DIAL AND MOUNTING PLATE REPLACEMENT
INITIAL SETUP:
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
Parts Manual (WP 0220) Figure 4002
(WP 0225, Table 1, Item 12)
Equipment Condition
Materials/Parts
High tank level switch removed. (WP 0187)
Locknut (WP 0226, Table 1, Item 56) Qty: 2
Low tank level switch removed. (WP 0189)
REMOVAL
Remove two locknuts (Figure 1, Item 6), screws (Figure 1, Item 5), four washers (Figure 1, Item 4), mounting
plate (Figure 1, Item 3), and dial (Figure 1, Item 2) from tank (Figure 1, Item 1). Discard locknuts.
2
1
3
5, 6
4
Figure 1. Dial and Mounting Plate Removal.
END OF TASK
INSTALLATION
Install dial (Figure 2, Item 2) and mounting plate (Figure 2, Item 3) on tank (Figure 2, Item 1) with two screws
(Figure 2, Item 5), four washers (Figure 2, Item 4), and two locknuts (Figure 2, Item 6).