INSTALLATION - Continued
CAUTION
Do not over-tighten nuts on circuit board. Failure to comply will result in damage to equipment.
11.
Install white wire (Figure 8, Item 9) and red wire (Figure 8, Item 10) on +24 vdc stud (Figure 8, Item 8) with nut
(Figure 8, Item 7).
12.
Install two black wires (Figure 8, Item 13) on ground stud (Figure 8, Item 14) with washer (Figure 8, Item 16)
and nut (Figure 8, Item 15).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
13.
Apply sealant to the threads of six screws (Figure 9, Item 3).
5
6
3, 4
Figure 9. Main Control Panel Tachometer/Hourmeter Installation.
14.
Install six washers (Figure 9, Item 4) and screws (Figure 9, Item 3) on main control box (Figure 9, Item 5) and
control panel (Figure 9, Item 6). Tighten six screws securely.
15.
Close control panel cover (Figure 10, Item 1) and secure with rubber t-handle (Figure 10, Item 2).