TM 5-3825-270-23&P
0103
INSTALLATION - Continued
7
8
9, 10
11
5
Figure 4. Main Control Panel Water Level High Indicator Installation.
NOTE
Install wires as noted prior to removal.
2.
Connect black wire (Figure 4, Item 7) to water high level indicator (Figure 4, Item 8).
3.
Connect green wire (Figure 4, Item 11) to water high level indicator (Figure 4, Item 8).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
4.
Apply sealant to the threads of six screws (Figure 5, Item 3).
5
6
3, 4
Figure 5. Main Control Panel Water Level High Indicator Installation.