Figure 4. Main Control Panel Tachometer/Hourmeter Removal.
Figure 7. Main Control Panel Tachometer/Hourmeter Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  601    602    603    604    605  606  607    608    609    610    611  
img
.
TM 5-3825-270-23&P
0102
REMOVAL - Continued
12.
Remove nut (Figure 5, Item 26), lockwasher (Figure 5, Item 27), and washer (Figure 5, Item 28) from stud
(Figure 5, Item 25).
NOTE
Note position of tachometer/hourmeter prior to removal to ensure proper installation.
13.
Remove retainer (Figure 5, Item 35) and tachometer/hourmeter (Figure 5, Item 36) from control panel (Figure
5, Item 6).
END OF TASK
INSTALLATION
NOTE
Install tachometer/hourmeter as noted prior to removal.
1.
Position tachometer/hourmeter (Figure 6, Item 36) in control panel (Figure 6, Item 6).
25
26, 27, 28
21
14
29
19
30, 31, 33
33
34
6
36
35
Figure 6. Main Control Panel Tachometer/Hourmeter Installation.
2.
Position retainer (Figure 6, Item 35) on tachometer/hourmeter (Figure 6, Item 36).
3.
Install retainer (Figure 6, Item 35) on stud (Figure 6, Item 25) with washer (Figure 6, Item 28), lockwasher
(Figure 6, Item 27), and nut (Figure 6, Item 26).
4.
Install retainer (Figure 6, Item 35) on stud (Figure 6, Item 19) with washer (Figure 6, Item 32), lockwasher
(Figure 6, Item 31), and nut (Figure 6, Item 30).
5.
Install nut (Figure 6, Item 34) on stud (Figure 6, Item 21).
6.
Install nut (Figure 6, Item 33) on stud (Figure 6, Item 14). Tighten nut until it is parallel with nut (Figure 6, Item
30).
7.
Position lockwashers (Figure 6, Item 29) on stud (Figure 6, Item 19) and stud (Figure 6, Item 14).