MAIN CONTROL PANEL BATTERY VOLTAGE GAUGE REPLACEMENT
Figure 4. Main Control Panel Battery Voltage Gauge Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  500    501    502    503    504  505  506    507    508    509    510  
img
.
TM 5-3825-270-23&P
0087
REMOVAL - Continued
5
6
3, 4
Figure 2. Main Control Panel Battery Voltage Gauge Removal.
NOTE
Tag and mark wires prior to removal to ensure proper installation.
3.
Remove wire connector (Figure 3, Item 9) from main control panel battery voltmeter gauge (Figure 3, Item 8).
6
7
8
9
Figure 3. Main Control Panel Battery Voltage Gauge Removal.
NOTE
Note position of main control panel battery voltmeter gauge prior to removal to ensure proper
installation.
4.
Remove nut (Figure 3, Item 7) and main control panel battery voltmeter gauge (Figure 3, Item 8) from control
panel (Figure 3, Item 6).
END OF TASK
INSTALLATION
NOTE
Install main control panel battery voltmeter gauge noted prior to removal.
0087-2