TM 5-3825-270-23&P
FIELD MAINTENANCE
CAB CONTROL BOX WATER SPRINKLER SWITCH (RIGHT) INOPERATIVE
INITIAL SETUP:
References (cont.)
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive
Universal Power Interface Kit (UPIK) Wire Harness
Water Distributor Operator Manual (TM
5-3825-270-10)
References
Cab Control Box Water Sprinkler Switch
Equipment Condition
Engine OFF. (TM 5-3825-270-10)
Universal Power Interface Kit (UPIK) harness
Cab Control Box Wiring Harness Replacement
connected to prime mover. (TM
5-3825-270-10)
Water Sprinkler Switch (Right) Inoperative
TROUBLESHOOTING PROCEDURE
CAB CONTROL BOX WATER SPRINKLER SWITCH (RIGHT) INOPERATIVE
STEP 1
Does main control panel RIGHT WATER SPRINKLER switch operate?
NOTE
If RIGHT WATER SPRINKLER switch operates on main control panel, fault can be isolated
to cab control box or universal power interface kit (UPIK) harness.
Attempt to operate right water sprinkler using main control panel RIGHT WATER SPRINKLER switch. (TM
5-3825-270-10)
CONDITION/INDICATION
Does main control panel RIGHT WATER SPRINKLER switch operate?
DECISION
No - Go to Right Water Sprinklers Switch Does Not Operate. (WP 0044)
Yes - Go to step 2. (Step 2 - Are cab control box and water distributor harnesses connected properly to prime
mover?)
STEP 2
Are cab control box and water distributor harnesses connected properly to prime mover?
1.
Push EMERGENCY STOP switch in to off position. (TM 5-3825-270-10)
2.
Check cab control box electrical connector.
0064-1