TM 5-3825-270-23&P
FIELD MAINTENANCE
UPIK WIRE HARNESS REPLACEMENT
INITIAL SETUP:
Materials/Parts (cont.)
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive
Tags, Identification, White (WP 0224, Table 1, Item
54)
Jack, Hyd, 20 Ton Cap (WP 0225, Table 1, Item
2)
Block, Filler Wood, 3 in. Thick (WP 0225, Table 1,
Personnel Required
Item 2)
Construction Equipment Repairer 91L (2)
Tap & Die Set (Screwdriver) (WP 0225, Table 1,
Item 2)
References
Materials/Parts
Compound, Sealing, Loctite 242 (WP 0224, Table
1, Item 19, 20, 21, 22)
Equipment Condition
Water tank drained. (TM 5382527010)
Hoses unstowed. (TM 5-3825-270-10)
Floating strainer unstowed. (TM 5-3825-270-10)
REMOVAL
1.
Open control panel cover (Figure 1, Item 2) by releasing rubber t-handle (Figure 1, Item 1).
1
2
Figure 1. UPIK Wire Harness Removal.
CAUTION
Do not allow control panel to hang by wires. Failure to comply may result in damage to
equipment.
2.
Remove six screws (Figure 2, Item 3) and washers (Figure 2, Item 4) from main control box (Figure 2, Item 5)
and control panel (Figure 2, Item 6).