Figure 6. UPIK Electrical Connection - Step 5.
CAB CONTROL BOX WATER LEVEL HIGH INDICATOR DOES NOT ILLUMINATE

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  364    365    366    367    368  369  370    371    372    373    374  
img
. . . .
TM 5-3825-270-23&P
0064
DECISION
No - Replace UPIK harness. (WP 0108) Verify problem is solved. (Step 6 - Does cab control box RIGHT WATER
SPRINKLER switch operate?)
Yes - Wiring in cab control box harness is faulty. Replace cab control box wiring harness. (WP 0206) Verify
problem is solved. (Step 6 - Does cab control box RIGHT WATER SPRINKLER switch operate?)
STEP 6
Does cab control box RIGHT WATER SPRINKLER switch operate?
1.
If disconnected, connect batteries. (WP 0085)
2.
Ensure water distributor is set up to be operated using cab control box. (TM 5-3825-270-10)
3.
Rotate EMERGENCY STOP switch to on position. (TM 5-3825-270-10)
4.
Operate water sprinklers using cab control box RIGHT WATER SPRINKLER switch.
RIGHT WATER
SPRINKLERS
SWITCH
Figure 8. Right Water Sprinkler Switch - Step 6.
CONDITION/INDICATION
Does cab control box RIGHT WATER SPRINKLER switch operate?
DECISION
No - If the problem still exists, it is possible that another fault exists or that another troubleshooting procedure
applies. If this was the first time through the task, restart the same symptom troubleshooting fault task.
Yes - Your original problem has been resolved.
END OF WORK PACKAGE
0064-6