TM 5-3825-270-23&P
0065
3.
Verify main control panel WATER LEVEL HIGH indicator illuminates.
WATER LEVEL
HIGH INDICATOR
Figure 2. Water Level High Indicator - Step 1.
CONDITION/INDICATION
Does main control panel WATER LEVEL HIGH indicator illuminate?
DECISION
No - Go to Water Level High Indicator Does Not illuminate. (WP 0045)
Yes - Go to step 2. (Step 2 - Are cab control box and water distributor harnesses connected properly to prime
mover?)
STEP 2
Are cab control box and water distributor harnesses connected properly to prime mover?
1.
Push EMERGENCY STOP switch in to off position. (TM 5-3825-270-10)
2.
Check cab control box electrical connector.
ELECTRICAL
CAB CONTROL
CONNECTOR
BOX
Figure 3. Cab Control Box - Step 2.
3.
Check prime mover UPIK air and electrical connections.