WATER PRESSURE ERRATIC - Continued
Figure 2. Water Pump Isolation Mounts - Step 2.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  121    122    123    124    125  126  127    128    129    130    131  
img
. . . . . . . . . .
TM 5-3825-270-23&P
0024
FIELD MAINTENANCE
EXCESSIVE WATER PUMP NOISE
INITIAL SETUP:
Tools and Special Tools
References (cont.)
Tool Kit, General Mechanic's: Automotive
Flex Element Replacement (WP 0147)
(WP 0225, Table 1, Item 12)
Water Distributor Operator Manual (TM
5-3825-270-10)
Water Pump Assembly Replacement (WP 0198)
References
Engine Module Replacement (WP 0128)
Field Level Preventive Maintenance Checks And
Equipment Condition
Services (PMCS) (WP 0069)
Engine OFF. (TM 5-3825-270-10)
Pump Drive Coupling Replacement (WP 0200)
TROUBLESHOOTING PROCEDURE
EXCESSIVE WATER PUMP NOISE
STEP 1
Are all water pump housing screws installed and tight?
Ensure all water pump housing screws are installed and tight. (WP 0069)
WATER PUMP
HOUSING SCREWS
WATER PUMP
HOUSING
SCREWS
Figure 1. Water Pump Housing Screws - Step 1.
CONDITION/INDICATION
Are all water pump housing screws installed and tight?
DECISION
No - Properly install and/or tighten all water pump housing screws. (WP 0128) Verify problem is solved. (Step
5 - Is there excessive water pump noise?)
Yes - Go to step 2. (Step 2 - Are water pump isolation mounts tight and free of damage?)
STEP 2
0024-1