• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
EXCESSIVELY LONG CRANK TIMES - Continued
Figure 2. Air Filter Restriction Indicator - Step 4.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  46    47    48    49    50  51  52    53    54    55    56  
img
. . .
TM 5-3825-270-23&P
0008
NOTE
The following chart describes battery voltage characteristics when measured with a
multimeter. This chart can be used to further isolate and troubleshoot batteries that may be
cause of problem.
6.
Note and compare multimeter reading to chart.
Table 1. Battery State Of Charge Voltage Table.
Percentage Of Full Charge
12 Volt DC System
24 Volt DC System
100%
12.7
25.4
90%
12.6
25.2
80%
12.5
25
70%
12.3
24.6
60%
12.2
24.4
50%
12.1
24.2
40%
12.0
24
30%
11.8
23.6
20%
11.7
23.4
10%
11.6
23.2
0%
<=11.6
<=23.2
CONDITION/INDICATION
Are water distributor batteries at 70% or more of full charge?
DECISION
No - Service (WP 0082), or replace batteries. (WP 0086) Verify problem is solved. (Step 9 - Is engine crank time
normal during engine starts?)
Yes - Go to step 4. (Step 4 - Does air filter restriction indicator indicate restriction?)
STEP 4
Does air filter restriction indicator indicate restriction?
NOTE
Sight glass on air restriction gauge will be red in color if restriction is present.
Visually inspect air filter restriction indicator.
0008-3