TM 5-3825-270-10
0058
VALVE
V5
Figure 3. Valve V5 - Step 3.
CONDITION/INDICATION
Is valve V5 completely closed?
DECISION
No - Fully close valve V5. (WP 0018) Verify problem is solved. (Step 5 - Does manual water turret operate at
full pressure (no more than 20% below normal)? Refer to Equipment Description and DataWP 0002) for normal
pressure readings.)
Yes - Go to step 4. (Step 4 - Is water pressure present low after ensuring proper operation of water
distributor?)
STEP 4
Is water pressure present low after ensuring proper operation of water distributor?
NOTE
Water pressure is directly proportional to engine speed. Any increase or decrease in engine
speed will effect the amount of water pressure at water stations.
Ensure engine speed is appropriate for desired water distributor performance. (WP 0015)
CONDITION/INDICATION
Is water pressure present low after ensuring proper operation of water distributor?
DECISION
No - Problem solved.
Yes - Problem not found. Notify maintenance personnel manual water turret pressure is low.