WATER LEVEL LOW INDICATOR STAYS ILLUMINATED
Figure 2. Valve V1 - Step 2.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  203    204    205    206    207  208  209    210    211    212    213  
img
. . . .
TM 5-3825-270-10
0057
OPERATOR MAINTENANCE
MANUAL WATER TURRET DOES NOT OPERATE
INITIAL SETUP:
Equipment Condition
Engine OFF. (WP 0015)
Water Pump Primed. (WP 0019)
TROUBLESHOOTING PROCEDURE
MANUAL WATER TURRET DOES NOT OPERATE
STEP 1
Is valve V6 in open position?
Observe valve V6 position.
VALVE
V6
Figure 1. Valve V6 - Step 1.
CONDITION/INDICATION
Is valve V6 in open position?
DECISION
No - Rotate valve V6 to open position. Verify problem is solved. (Step 3 - Does manual water turret operate?)
Yes - Go to step 2. (Step 2 - Is valve V1 in open position?)