Figure 2. Emergency Stop Switch - Step 2.
Figure 2. Emergency Stop Switch - Step 2.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  199    200    201    202    203  204  205    206    207    208    209  
img
. . . . . .
TM 5-3825-270-10
0054
OPERATOR MAINTENANCE
WATER LEVEL LOW INDICATOR DOES NOT ILLUMINATE
INITIAL SETUP:
References
Equipment Condition
Discharge From Hose Reel Assembly (WP 0017)
Engine OFF. (WP 0017)
Empty Tank Without Pump (WP 0023)
TROUBLESHOOTING PROCEDURE
WATER LEVEL LOW INDICATOR DOES NOT ILLUMINATE
NOTE
Water level low indicator will illuminate when water distributor tank level falls below 300
gallons (1,136 liters) of water.
STEP 1
Is water distributor tank filled with less than 300 gallons (1,136 liters) of water?
Visually inspect water level indicator on front of water distributor tank.
WATER LEVEL
INDICATOR
Figure 1. Water Level Indicator - Step 1.
CONDITION/INDICATION
Is water distributor tank filled with less than 300 gallons (1,136 liters) of water?
DECISION
No - Drain water distributor until water level indicator reads 300 gallons (1,136 liters) or less. (WP 0023) Verify
problem is solved. (Step 2 - Does WATER LEVEL LOW indicator illuminate?)
Yes - Notify maintenance personnel WATER LEVEL LOW indicator does not illuminate.
STEP 2
Does WATER LEVEL LOW indicator illuminate?
1.
Rotate EMERGENCY STOP switch to on position.
0054-1