0053
OPERATOR MAINTENANCE
WATER LEVEL HIGH INDICATOR DOES NOT ILLUMINATE
INITIAL SETUP:
References
Equipment Condition
Discharge From Hose Reel Assembly (WP 0017)
Engine OFF. (WP 0017)
Load Tank At Strainer With System Pump And 3"
Hose (WP 0020)
TROUBLESHOOTING PROCEDURE
WATER LEVEL HIGH INDICATOR DOES NOT ILLUMINATE
NOTE
Water level high indicator will illuminate when water distributor tank is filled with 3,000 gallons
(11,355 liters) of water.
STEP 1
Is water distributor tank filled with 3,000 gallons (11,355 liters) of water?
Visually inspect water level indicator on front of water distributor tank.
WATER LEVEL
INDICATOR
Figure 1. Water Level Indicator - Step 1.
CONDITION/INDICATION
Is water distributor tank filled with 3,000 gallons (11,355 liters) of water?
DECISION
No - Fill water distributor until water level indicator reads 3,000 gallons (11,355 liters).WP 0020) Verify problem
(
is solved. (Step 2 - Does WATER LEVEL HIGH indicator illuminate?)
Yes - Notify maintenance personnel WATER LEVEL HIGH indicator does not illuminate.
STEP 2
Does WATER LEVEL HIGH indicator illuminate?
1.
Rotate EMERGENCY STOP switch to ON position.