TM 5-3825-270-10
0058
OPERATOR MAINTENANCE
MANUAL WATER TURRET OUTPUT LOW
INITIAL SETUP:
References
References (cont.)
General Information (WP 0001)
Discharge From Water Turret Assembly
Equipment Description and Data (WP 0002)
(WP 0015)
Circulate Tank With Pump To Blend Or Rinse
Prime Fully Drained Pump (WP 0019)
(WP 0018)
Equipment Condition
Engine ON. (WP 0015)
Water pump primed. (WP 0019)
TROUBLESHOOTING PROCEDURE
MANUAL WATER TURRET OUTPUT LOW
STEP 1
Is valve V6 completely open?
Verify valve V6 position.
VALVE
V6
Figure 1. Valve V6 - Step 1.
CONDITION/INDICATION
Is valve V6 completely open?
DECISION
No - Fully open valve V6. (WP 0015) Verify problem is solved. (Step 5 - Does manual water turret operate at full
pressure (no more than 20% below normal)? Refer to Equipment Description and Data (WP 0002) for normal
pressure readings.)
Yes - Go to step 2. (Step 2 - Is valve V1 completely open?)
STEP 2
0058-1