MANUAL WATER TURRET OUTPUT LOW
Figure 3. Valve V5 - Step 3.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  206    207    208    209    210  211  212    213    214    215    216  
img
. . .
TM 5-3825-270-10
0058
Is valve V1 completely open?
Verify valve V1 position.
VALVE
V1
Figure 2. Valve V1 - Step 2.
CONDITION/INDICATION
Is valve V1 completely open?
DECISION
No - Fully open valve V1. (WP 0015) Verify problem is solved. (Step 5 - Does manual water turret operate at full
pressure (no more than 20% below normal)? Refer to Equipment Description and Data (WP 0002) for normal
pressure readings.)
Yes - Go to step 3. (Step 3 - Is valve V5 completely closed?)
STEP 3
Is valve V5 completely closed?
Verify valve V5 position.
0058-2