• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
GRAVITY FED SPRINKLER BAR DOES NOT OPERATE - Continued
Figure 2. Gravity Fed Sprinkler Bar - Step 2.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  211    212    213    214    215  216  217    218    219    220    221  
img
. . . . .
TM 5-3825-270-10
0060
OPERATOR MAINTENANCE
GRAVITY FED SPRINKLER BAR STREAM LOW
INITIAL SETUP:
References
Equipment Condition
Discharge From Gravity Sprinkler Bar (WP 0013)
Engine OFF. (WP 0015)
TROUBLESHOOTING PROCEDURE
GRAVITY FED SPRINKLER BAR STREAM LOW
NOTE
Water pressure at particular water stations may be reduced by partially closed valves.
STEP 1
Is valve V8 completely open?
Verify valve V8 position.
VALVE V8
Figure 1. Valve V8 - Step 1.
CONDITION/INDICATION
Is valve V8 completely open?
DECISION
No - Rotate valve V8 to full open position. Verify problem is solved. (Step 2 - Is gravity fed sprinkler bar stream
normal?)
Yes - Notify maintenance personnel gravity fed sprinkler bar pressure low.
STEP 2
Is gravity fed sprinkler bar stream normal?
Operate gravity fed sprinkler bar. (WP 0013)
0060-1


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.