Figure 5. Maintenance Display
Figure 6. Maintenance Display

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  495    496    497    498    499  500  501    502    503    504    505  
img
.
TM 5-3820-276-10-2
0202
Table 3.
PMCS - Welder/Generator - After Drilling Equipment Operation.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
WARNING
The Water Well Drilling System
presents numerous falling
hazards. Use care when working
on top of equipment. Failure to
comply may result in injury or
death to personnel. Seek medical
attention in the event of an injury.
Take extra precaution and wear
proper protection, such as gloves
and goggles, when inspecting
items in the hot engine
compartment area. Failure to
comply may result in injury or
death to personnel. Seek medical
attention in the event of an injury.
CAUTION
Ensure equipment is disconnected from
auxiliary power receptacles during startup
and shutdown. Some equipment can be
adversely affected by changes in
frequency as engine rpm changes during
startup and shutdown. Failure to comply
may result in damage to equipment.
NOTE
Engine hours are shown on the
maintenance display for maintenance
interval purposes, and are retrieved with
the engine off and engine control switch in
the RUN/IDLE position.
NOTE
1
After
Oil Change
Indicator/
Oil hours start at 100 and count down to 0
Maintenance
(a flashing wrench icon will appear
Display
indicating oil change is due).
Negative hours indicate when past
recommended oil change interval.
0202-11
02/13/2013root(pmcswp)wpno(I20002)