Table 2. PMCS - Welder/Generator - During Drilling Equipment Operation
Figure 5. Maintenance Display

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  493    494    495    496    497  498  499    500    501    502    503  
img
TM 5-3820-276-10-2
0202
Table 2.
PMCS - Welder/Generator - During Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
NOTE
The following events may occur during
operation:
Low Fuel Shutdown: Engine will shut off
prior to running out of fuel to prevent loss
of fuel in the system with maintenance
display reading noFUEL. If this happens,
add fuel as required.
High Coolant Temperature Shutdown:
Engine will shut off if coolant temperature
is too high with maintenance display
reading HI H2O. If this happens, add
coolant as required.
Low Oil Pressure Shutdown: Engine will
shut off if oil pressure is too low with
maintenance display reading LO OIL. If this
happens, add oil as required.
1
During
Operational
Start welder/generator (Volume 1, WP 0045) to
Check
perform the PMCS checks that follow.
2
During
Engine
Check and/or listen for exhaust leakage, excessive
Engine has exhaust
smoke, unusual noise, rough running, and misfiring.
leakage, excessive
smoke, unusual noise,
rough running, or
misfiring. Notify
maintenance.
3
During
Maintenance
Monitor maintenance display (Figure 5, Item 1) for
Maintenance display does
Display
illumination, and proper reading and operation.
not illuminate, read/
operate properly. Notify
maintenance.
0202-9