Figure 31. Fuel Level.
Figure 34. Fault Indicator.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  476    477    478    479    480  481  482    483    484    485    486  
img
. .
TM 5-3820-276-10-2
0201
Table 4.
PMCS - PAC - Before Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
WARNING
22
Before
Fuel and Air
Lines
Do not use your bare hands to check for
fluid leaks. Fluid leakage that is under
pressure can penetrate your skin. Always
use a board or cardboard when you check
for a leak. If fluid is injected into your skin,
seek medical aid immediately. Failure to
comply may result in injury or death to
personnel. Seek medical attention in the
event of an injury.
Check air line routing and connections (Figure 33, Item Fuel or air lines are loose
1) and fuel lines (Figure 33, Item 2) for damage.
or damaged. Notify
maintenance.
1
2
WWDS00016
Figure 33. Fuel and Air Lines.
Table 5.
PMCS - PAC - During Drilling Equipment Operation.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
1
During
Fault Indicator
1. Check fault indicator (Figure 34, Item 1) for fault
Fault indicator displays a
codes in engine section.
fault in engine section
(WP 0177). Notify
maintenance.
0201-24