Figure 22. Hydraulic Control Manifold, Levers, Pump, and Hoses.
Figure 25. Hydraulic Oil Cooler Fins.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  436    437    438    439    440  441  442    443    444    445    446  
img
. .
TM 5-3820-276-10-2
0200
Table 4.
PMCS - MCS - Before Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
1
WWDS00722
Figure 23. Shaker Grease Fitting.
NOTE
12
Before
Desander Pump
Grease Fittings
Desander pump has a total of three grease
fittings.
Lubricate desander pump grease fittings (Figure 24,
Item 1) with three to five pumps of grease (WP 0233).
1
1
WWDS00723
Figure 24. Desander Pump Grease Fittings.
13
Before
Hydraulic Oil
Check hydraulic oil cooler (Figure 25, Item 1) for
Hydraulic oil cooler
Cooler Fins
obstructions or damage. Remove any obstructions.
damaged. Notify
maintenance.
0200-20
02/13/2013root(pmcswp)wpno(I40001)