Table 4.
PMCS - MCS - Before Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
1
2
3
WWDS00958
Figure 21. Hydraulic Oil Cooler Fan and Wiring.
2. Check hydraulic oil cooler fan guard (Figure 21, Item Hydraulic oil cooler fan
2) for obstructions or damage. Remove any
guard damaged. Notify
obstructions.
maintenance.
3. Check hydraulic oil cooler wiring (Figure 21, Item 3)
Wire connections loose,
for broken wires, loose connections, and missing
missing insulation, or
insulation.
wires broken. Notify
maintenance.
NOTE
10
Before
Hydraulic
Control Manifold,
Check all hoses and connections for
Pump, Levers,
security or missing hardware as you go
Hoses, and
around and do other PMCS checks.
Gauges
1. Check hydraulic pump (Figure 22, Item 1), and
Hydraulic pump or hoses
hoses for leaks or missing hardware.
leaking, or missing
hardware. Notify
maintenance.
0200-18