TM 10-4630-206-12&P
UNIT MAINTENANCE
SEWAGE EJECTION PUMP, LAUNDRY
NSN 4630-01-413-2606
SEWAGE EJECTION PUMP, GENERAL PURPOSE
NSN 4630-01-413-2608
SEWAGE EJECTION PUMP, WASTE WATER EVACUATION
NSN 4630-01-505-3746
TANK ASSEMBLY
REPLACE
INITIAL SETUP
Tools
Personnel Required
One
Tool Kit General Mechanics Automotive (Item 3, WP 0025 00)
Materials/Parts
Equipment Condition
Tank empty
All hoses disconnected
All circuit breakers OFF
Power cord disconnected
REPLACE
Replace Bulkhead Fitting
WARNING
Ensure that the SEP has been thoroughly cleaned with chlorine
solution and rinsed prior to any inspection or service to the interior.
Failure to do so may result in serious illness or death to personnel.
1. Remove coupling dust cap (1) from aluminum or brass coupling half (2).
2. Unscrew coupling half from bulkhead fitting (3).
3. Remove plug (4) from outside of tank.
4. Remove nut (5), bulkhead fitting (3), and gasket from tank.
5. Install bulkhead fitting and gasket, and secure with nut.
6. Install aluminum or brass coupling half (2) onto fitting.
7. Install coupling dust cap (1) onto coupling half.
5
4
2
3
2
1
1
0014 00-1