TM 10-4320-344-242.11.2 Stud and Thread Repair. (Continued)Compressed air can blow dust into the eyes.Wear eye protection.Do notexceed 30 psi (207 kPa) air pressure.b .Clean newly bored hole using compressed air.c.Lubricate thread cutting tap (3) with transmission oil.d .Using tap handle and tap (3), cut new threads.Compressed air can blow dust into the eyes.Wear eye protection.Do notexceed 30 psi (207 kPa) air pressure.Dry cleaning solvent is highly toxic and canignite organic materials, nitrates, carbides, and chlorates.Weareye, skin, and respiratory protection.Use only in well ventilatedarea.e .Using compressed air, blow out dirt and any loose metal chips in threads.f .Using rag dampened with cleaning solvent, clean hole.2-42
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business