TM 10-4320-344-24SECTION V. UNIT MAINTENANCE PROCEDURES2.11 GENERAL MAINTENANCE PROCEDURES.2.11.1 Data Plate Replacement.This task covers:2.11.1.1 Removal2 .11 . 1 . 2 I n s t a l l a t i o nINITIALSETUPUseWithTrailer-Mounted Pump Assemblies609-A, 609-C and US636HCCD-1ToolsGeneral Mechanic’s AutomotiveTool Kit, Appendix B, SectionIII, Item 1Riveter, Blind, Appendix B,Section III, Item 4Material/PartsRivets (TM 10-4320-344-24P)EquipmentConditionsPumping station shut down, TM10-4320-344-10.General Safety InstructionsTo prevent rolling or sliding, do not workon equipment that is not securelys t a b i l i z e d .Do not work on equipment without followingstandard shop safety precautions.This procedure applies to all rivet mounted data plates on all pumpingassemblies. The procedures for screw mounted and adhesive backed data platesare similar.2.11.1.1 Removal.a .Remove four rivets (Figure 2-5, 1).b .Remove data plate (2).2.11.1.2 Installation.a .Position data plate (2) on enclosure (3).b .Using blind riveter, install four rivets (1).2-37NOTE