2.23.15 ShockAbsorberMaintenance,Models609-Aand609-C.This task covers:2.23.15.1 Removal2 .23 .1 5 . 3 I n s t a l l a t i on2 .23 .1 5 . 2 R e p a irINITIALSETUPToolsGeneral Safety InstructionsGeneral Mechanic’s AutomotiveDo not work on equipment that is notTool Kit,Appendix B, SectionI I I,securely stabilized to prevent rollingItem 1o r s l i d i n g .Material/PartsDo not work on equipment without follow-ing standard shop safety practices.Locknut (TM 10-4320-344-24P)Equipment Conditionspumping station shut down, TM 10-4320-344-10.This procedure applies to Model 609-A.The procedure for Model 609-C iss i m i l a r.2.23.15.1 Removal.Figure 2-184.Shock Absorber Maintenance, Models 609-A and 609-C.2-413TM 10-4320-344-24