TM 10-4320-344-24
2.23.13 Lights Miantenance.
This task covers:
2.23.13.1 Removal
2 .
2
3 .1 3 . 3 R e p a i r
2.23.13.2 Testing
2.23.13.4 Installation
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Automotive
Tool Kit, Appendix B, Section
Pumping station shut down, TM 10-4320-344
III, Item 1
10.
Multimeter, Appendix B, Section
General Safety Instructions
III, Item 2
Do not work on equipment that is not
Material/Parts
securely stabilized-to prevent rolling
o r s l i d i n g.
Tags, Appendix C, Item 31
Lock Washers (TM 10-4320-344-24P
Do not work on equipment without follow-
ing standard shop safety practices.
This procedure applies to Model US636HCCD-1.
The procedures for Models
609-A and 609-C are similar.
2.22.14.1 Removal.
a .
Remove service light (Figure 2-182, 1) as follows:
Do not apply excessive pressure to bulb when removing bulb.
Failure to obey
t h i s
(1)
(2)
(3)
(4)
warning may result- in personal injury.
Remove two lens mounting screws (2), lens (3), and bulb (4).
Clean socket of any dirt, debris, or corrosion.
Tag and disconnect two wires (5) from wiring harness connectors.
Remove two service light mounting nuts
light (l). Discard lock washers (7).
b .
Remove clearance light (8) as follows:
(6), lock washers (7), and service
Do not apply excessive pressure to bulb when removing bulb.
Failure to obey
this warning may result in personal injury.
(1) Pry lens (9) from clearance light (8) and remove bulb (10).
(2) Clean dirt, debris, or corrosion from socket.
(3) Tag and unplug wire (11) from wiring harness connector.
(4) Remove two clearance light mounting nuts (12), lock washers (13), screws
(14), and clearance light (8).
Discard lock washers (13).
2-408
NOTE