TM 10-4320-344-242.23.13 LightsMiantenance.This task covers:2.23.13.1 Removal2 .23 .1 3 . 3 R e p a i r2.23.13.2 Testing2.23.13.4 InstallationINITIAL SETUPToolsEquipment ConditionsGeneral Mechanic’s AutomotiveTool Kit, Appendix B, SectionPumping station shut down, TM 10-4320-344III, Item 110.Multimeter, Appendix B, SectionGeneral Safety InstructionsIII, Item 2Do not work on equipment that is notMaterial/Partssecurely stabilized-to prevent rollingo r s l i d i n g.Tags, Appendix C, Item 31Lock Washers (TM 10-4320-344-24PDo not work on equipment without follow-ing standard shop safety practices.This procedure applies to Model US636HCCD-1.The procedures for Models609-A and 609-C are similar.2.22.14.1 Removal.a .Remove service light (Figure 2-182, 1) as follows:Do not apply excessive pressure to bulb when removing bulb.Failure to obeyt h i s(1)(2)(3)(4)warning may result- in personal injury.Remove two lens mounting screws (2), lens (3), and bulb (4).Clean socket of any dirt, debris, or corrosion.Tag and disconnect two wires (5) from wiring harness connectors.Remove two service light mounting nutslight (l). Discard lock washers (7).b .Remove clearance light (8) as follows:(6), lock washers (7), and serviceDo not apply excessive pressure to bulb when removing bulb.Failure to obeythis warning may result in personal injury.(1) Pry lens (9) from clearance light (8) and remove bulb (10).(2) Clean dirt, debris, or corrosion from socket.(3) Tag and unplug wire (11) from wiring harness connector.(4) Remove two clearance light mounting nuts (12), lock washers (13), screws(14), and clearance light (8).Discard lock washers (13).2-408NOTE