2.16.27 Fuel Rack Cable Replacement, Model 609-A.
This task covers:
2.16.27.1 Removal
2 .
1
6 .2 7 . 2 I n s t a l l a t i o n
INITIAL SETUP
Tools
General Mechanics Automotive
Tool Kit, Appendix B, Section III,
Item 1
Material/Parts
Straps, Electrical Tiedown, Appendix C,
Item 29
Equipment Conditions
Pumping station shut down, TM 10-4320-
344-10.
Battery disconnected, paragraph 2.15.2.
Equipment Conditions (Continued)
Control Panel Cover Assembly removed,
paragraph 2.16.1.
General Safety Instructions
Do not work on equipment that is not
securely stabilized to prevent rolling or
s l i d i n g.
Do not work on equipment with battery
connected. Electrocution hazard is
present if battery is connected.
Do not work on equipment without following
standard shop safety precautions.
2.16.27.1 Removal.
a.
b.
c .
d.
e .
f .
Do not work on equipment that is not securely stabilized to prevent
rolling or sliding. Ensure both wheels of equipment have chocks that
are secure.
Do not work on equipment with battery connected. Electrocution hazard is
present if battery is connected.
Failure to obey these warnings may result in serious personal injury.
Push fuel rack handle (Figure 2-78, 1) fully in and turn clockwise to LOCK
p o s i t i o n.
Loosen screw (2) and remove universal wire stop (3) from end of fuel rack
c a b l e ( 4 ).
Remove nut (5), lock washer (6), cable clamp mounting bolt (7), and cable
clamp (8).
Remove and discard electrical tiedown straps (9) securing fuel rack cable (4)
to wiring harness (10).
Unscrew cable mounting nut (11). Remove cable mounting nut (11) and lock
washer (12) from threaded portion of fuel rack handle (1).
Using fuel rack handle (1), pull fuel rack cable (4) through grommet in rear
panel plate (13), pressure regulator mounting bracket (14), and control panel
(15) and remove cable mounting nut (11) and lock washer (12).
TM 10-4320-344-24