TM 10-4320-344-24
2.16.29 Cold Start Aid Cable Replacement, Model 609-C.
This task covers:
2.16.29.1 Removal
2.16.29.2 Installation
INITIAL SETUP
Tools
Equipment Conditions (Continued)
General Mechanics Automotive
Battery disconnected, paragraph 2.15.3.
Tool Kit, Appendix B, Section III,
Item 1
General Safety Instructions
Equipment Conditions
Do not work on equipment without following
standard shop safety precautions.
Pumping station shut down, TM 10-4320-
344-10.
2.16.29.1 Removal.
a.
Open Cold Start Aid access door (Figure 2-80,
1) on pumping assembly (2).
b.
Loosen screw on universal wire stop (3) and remove cold start aid cable (4)
from actuator (5).
c .
Loosen wire nut stop (6) and remove cold start aid cable (4) from bottom
bracket (7).
d.
Remove screw (8), cable clamp (9), and pull cold start aid cable (4) out
through grommet (10).
e .
Remove lock nut (11), handle (12), and cold start aid cable (4) from pumping
assembly (2).
2.16.29.2 Installation.
a.
Install cold start aid cable (4) in pumping assembly (2).
b.
Install handle (12) on cold start aid cable (4) and secure with lock nut (11).
c .
Insert cold start aid cable (4) through grommet (10) and secure with cable
clamp (9) and screw (8).
d .
Insert cold start aid cable (4) through wire nut stop (6), bracket (7), and
universal wire stop (3) on actuator (5). Tighten universal wire stop (3).
Ensure, when handle is pushed completely down, actuator is in fully down
(released) positioned and when handle is pulled out actuator can be raised to
maximum open position.
e.
Loosen universal wire stop (3) and adjust cold start aid cable (4) as required
to ensure proper operation.
f .
Tighten wire nut stop (6) and universal wire stop (3) and close Cold Start Aid
access door (1) on pumping assembly (2).
2-203
NOTE