TM 10-4320-344-242.16.30.2 Repair.a .Inspect all mounting hardware for damage.b .R e p l a c e a l l d e f e c t i v e c o m p o n e n t s.2.16.30.3 Installation.Wrap antiseize tape in direction of threads on all pipe threads prior toi n s t a l l a t i o n.a.Install two clips (12) on control panel frame (11).b.Insert pressure regulator (5) in control panel frame (11) and secure with twomounting bolts (10).Use caution when closing cover to prevent damage to electrical connections. Donot attempt to rapidly move cover.c .Carefully close cover (9) and secure with four cover mounting screws (8).d .Install pipe elbows (4 and 7) in pressure regulator (5).e .Install pipe nipple (6) on pipe elbow (7).f .Connect suction hose assembly (3) to pipe elbow (4).g .Refer to tags and install wiring harness connectors (1 and 2). Remove anddiscard tags.2-207N O T E