TM 10-4320-344-24
2.16.32 Governor Control Module Maintenance, Model 609-C.
This task covers:
2.16.32.1 Removal
2.16.32.3
Installation
2 .
1
6 .3 2 . 2 R e p a ir
2.16.32.4 Adjustment
INITIAL SETUP
Tools
General Mechanics Automotive
Tool Kit, Appendix B, Section III,
Item 1
Material/Parts
Lock Washers (TM 10-4320-344-24P
Equipment Conditions
Pumping station shut down, TM 10-4320-
344-10.
Equipment Conditions (Continued)
Battery disconnected, paragraph 2.15.3.
General Safety Instructions
Do not work on equipment that is not
securely stabilized to prevent rolling or
s l i d i n g.
Do not work on equipment with battery
connected. Electrocution hazard is
present if battery is connected.
Do not work on equipment without following
standard shop safety precautions.
2.16.32.1 Removal.
Do not work on equipment with battery connected. Electrocution hazard is
present if battery is connected. Failure to obey this warning may result in
serious personal injury.
a.
Open control panel door assembly (Figure 2-85, 1) and control panel (2).
b.
Disconnect electrical connector P6 (3) from governor control module (4).
c .
Remove four screws (5), lock washers (6), one cable clamp (7), and governor
control module (4) from control panel assembly (8). Discard lock washers (6).
2.16.32.2 Repair.
a .
Inspect mounting hardware for damage.
b .
Replace all defective components.
2.16.32.3 Installation.
a .
Position governor control module (4) in control panel assembly (8) and secure
with cable clamp (7), four new lock washers (6), and screws (5).
b .
Connect electrical connector P6 (3) to governor control module (4).
2-212