TM 10-4320-344-242.16.32 GovernorControlModuleMaintenance,Model609-C.This task covers:2.16.32.1 Removal2.16.32.3 Installation2 .16 .3 2 . 2 R e p a ir2.16.32.4 AdjustmentINITIALSETUPToolsGeneral Mechanic’s AutomotiveTool Kit, Appendix B, Section III,Item 1Material/PartsLock Washers (TM 10-4320-344-24PEquipment ConditionsPumping station shut down, TM 10-4320-344-10.EquipmentConditions(Continued)Battery disconnected, paragraph 2.15.3.GeneralSafetyInstructionsDo not work on equipment that is notsecurely stabilized to prevent rolling ors l i d i n g.Do not work on equipment with batteryconnected. Electrocution hazard ispresent if battery is connected.Do not work on equipment without followingstandard shop safety precautions.2.16.32.1 Removal.Do not work on equipment with battery connected. Electrocution hazard ispresent if battery is connected. Failure to obey this warning may result inserious personal injury.a.Open control panel door assembly (Figure 2-85, 1) and control panel (2).b.Disconnect electrical connector P6 (3) from governor control module (4).c .Remove four screws (5), lock washers (6), one cable clamp (7), and governorcontrol module (4) from control panel assembly (8). Discard lock washers (6).2.16.32.2 Repair.a .Inspect mounting hardware for damage.b .Replace all defective components.2.16.32.3 Installation.a .Position governor control module (4) in control panel assembly (8) and securewith cable clamp (7), four new lock washers (6), and screws (5).b .Connect electrical connector P6 (3) to governor control module (4).2-212