TM 5-4320-302-14
4-37. STARTER MOTOR (CONT)
Location/Item
Action
Remarks
TEST/INSPECTION
2. Relay and
Remove. Test and inspect relay. If relay does
starter
not activate when excited with ground and
+12 vdc from 12 vdc power supply, the unit
is not operating properly. Test starter with
ground and +12 vdc. If starter does not run
and activate pinion, it is malfunctioning. If
repairable, notify direct support and replace
starter motor and relay.
INSTALLATION/
REPLACEMENT
3. Starter with
Support starter and relay, and install hex bolts
relay
and washers. Make sure starter pinion is cor-
rectly alined with flywheel ring gear. Tighten
bolts securely.
4. Starter elec-
Install tagged electrical system wires and posi-
trical system
tive battery cable in accordance with paragraphs
wiring and
4-13 and 4-15. Tighten lug nuts securely.
positive bat-
tery cable
5. Ground bat-
Install. Tighten lug nuts securely.
tery cable
SYSTEM TEST
WARNING
Carbon monoxide is produced by the internal combustion
engine of this pump. Death may result if personnel fail to
observe safety precautions.
Carbon monoxide is a colorless, odorless, deadly poisonous
gas which, when breathed, deprives the body of oxygen and
causes suffocation. Exposure to air contaminated with car-
bon monoxide produces symptoms of headache, dizziness, loss
of muscle control, or apparent drowsiness. Coma, permanent
brain damage, or death can result from severe exposure.
4-176